Supra LoRad MD06-EU/SP

4% unter UVP

Preis:
Sonderpreis€ 269,00 UVP€ 279,00

inkl. MwSt. Versandkosten werden im Checkout berechnet.

Lagerbestand:
Auf Lager

GPSR-Konformitätsinformationen

Allgemeine Informationen

CE-Kennzeichnung: Ja

Beschreibung

LoRad Shielded Mains Blocks in Aluminium 

The mains blocks are fully shielded from radiated electric fields by means of their aluminium chassis.
The conductive chassis drains the interference down to ground. It has to be connected to an earthed socket with an earthed mains cable, in order to work properly. For a useful degree of shielding and immunity, the mains block should be combined and employed with SUPRA LoRad shielded mains cables. 

SUPRA NIF Transient Filter 
All models are equipped with SUPRA NIF (Non-Intrusive Filtering), a mild transient filter which will not influence the transient properties of the equipment. SUPRA NIF is developed by Ben Duncan Research in England.

3-Way Surge Protection
The SP-models, i.e MD06-BS/SP, MD06-EU/SP and MD06-US/SP, are all equipped with SUPRA’s surge protection device which protects all three ways: Live to Earth, Neutral to Earth and Live to Neutral. Many other surge protectors are only Live to Neutral, and do not protect against field surges by proximate lightning. Lightning is always referred to earth.
For a correct and safe 3-way surge protection, the mains block has to be connected to an earthed wall socket.

MD06-EU/SP
6 EU sockets, Schuko. 
Input connector: IEC-320 
10 Amp Fuse 
NIF transient filter
3-way Surge Protection.
 
For a correct and safe 3-way surge protection, the mains block has to be connected to an earthed wall socket.

Technische Daten

Bauart geschirmte Netzleiste mit Filter und Überspannungsschutz
Steckdosen 6 × Schuko (Supra MCH-16/EU)
Eingang Supra MCH-10 (IEC C14) mit Sicherung 10 A träge
Belastbarkeit 10 A / 250 V / 2.400 W
Innenverdrahtung 2,5 mm² OFC-Kupfer
Filter NIF-Filter (Non-Intrusive Filtering, Ben Duncan Research), Dämpfung bis 40 dB; Dose 1 ungefiltert
Überspannungsschutz 3-Wege (L–E, N–E, L–N), Typ 3; Up = 2,0 kV (L–N), 2,05 kV (L/N–E)
Gehäuse Aluminium, geschirmt; Wandhalterung und Gummifüße im Lieferumfang
Querschnitt Gehäuse 90 × 50 mm (B × H)
Gewicht 1,40 kg

Änderungen vorbehalten.

Gewährleistung & Garantie

Gewährleistung
2 Jahre
Herstellergarantie
2 Jahre

Käufe ab 1. Oktober 2026: Wählen Sie bei einem Mangel die Reparatur statt eines Austauschs, verlängert sich die Gewährleistung einmalig um 12 Monate.

So bewerten Kunden unser Geschäft

{"id":3521494941779,"title":"Supra LoRad MD06-EU\/SP","handle":"supra-lorad-md06-eu-sp","description":"\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv id=\"description\" class=\"tab-pane active\"\u003e\u003cspan class=\"wysiwyg-font-size-larger\"\u003e\u003cb\u003eLoRad Shielded Mains Blocks in Aluminium \u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab-pane active\"\u003e\n\u003cbr\u003eThe mains blocks are fully shielded from radiated electric fields by means of their aluminium chassis.\u003c\/div\u003e\n\u003cdiv class=\"tab-pane active\"\u003eThe conductive chassis drains the interference down to ground. It has to be connected to an earthed socket with an earthed mains cable, in order to work properly. For a useful degree of shielding and immunity, the mains block should be combined and employed with SUPRA LoRad shielded mains cables. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eSUPRA NIF Transient Filter \u003c\/b\u003e\u003cbr\u003eAll models are equipped with SUPRA NIF (Non-Intrusive Filtering), a mild transient filter which will not influence the transient properties of the equipment. SUPRA NIF is developed by Ben Duncan Research in England.\u003cbr\u003e\u003cbr\u003e\u003cb\u003e3-Way Surge Protection\u003c\/b\u003e\u003cbr\u003eThe SP-models, i.e MD06-BS\/SP, MD06-EU\/SP and MD06-US\/SP, are all equipped with SUPRA’s surge protection device which protects all three ways: Live to Earth, Neutral to Earth and Live to Neutral. Many other surge protectors are only Live to Neutral, and do not protect against field surges by proximate lightning. Lightning is always referred to earth.\u003cbr\u003e\u003cspan\u003eFor a correct and safe 3-way surge protection, the mains block has to be connected to an earthed wall socket.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane active\"\u003e\n\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cb\u003eMD06-EU\/SP\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e6 EU sockets, Schuko. \u003c\/div\u003e\n\u003cdiv\u003eInput connector: IEC-320 \u003c\/div\u003e\n\u003cdiv\u003e10 Amp Fuse \u003c\/div\u003e\n\u003cdiv\u003eNIF transient filter\u003c\/div\u003e\n\u003cdiv\u003e3-way Surge Protection.\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003eFor a correct and safe 3-way surge protection, the mains block has to be connected to an earthed wall socket.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv data-techdaten=\"hifiteam\"\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBauart\u003c\/td\u003e\n\u003ctd\u003egeschirmte Netzleiste mit Filter und Überspannungsschutz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteckdosen\u003c\/td\u003e\n\u003ctd\u003e6 × Schuko (Supra MCH-16\/EU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEingang\u003c\/td\u003e\n\u003ctd\u003eSupra MCH-10 (IEC C14) mit Sicherung 10 A träge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBelastbarkeit\u003c\/td\u003e\n\u003ctd\u003e10 A \/ 250 V \/ 2.400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInnenverdrahtung\u003c\/td\u003e\n\u003ctd\u003e2,5 mm² OFC-Kupfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter\u003c\/td\u003e\n\u003ctd\u003eNIF-Filter (Non-Intrusive Filtering, Ben Duncan Research), Dämpfung bis 40 dB; Dose 1 ungefiltert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eÜberspannungsschutz\u003c\/td\u003e\n\u003ctd\u003e3-Wege (L–E, N–E, L–N), Typ 3; Up = 2,0 kV (L–N), 2,05 kV (L\/N–E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGehäuse\u003c\/td\u003e\n\u003ctd\u003eAluminium, geschirmt; Wandhalterung und Gummifüße im Lieferumfang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuerschnitt Gehäuse\u003c\/td\u003e\n\u003ctd\u003e90 × 50 mm (B × H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGewicht\u003c\/td\u003e\n\u003ctd\u003e1,40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eÄnderungen vorbehalten.\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n","published_at":"2019-04-25T11:40:50+02:00","created_at":"2019-04-25T11:59:41+02:00","vendor":"Supra","type":"netzleiste","tags":["spo-disabled"],"price":26900,"price_min":26900,"price_max":26900,"available":true,"price_varies":false,"compare_at_price":27900,"compare_at_price_min":27900,"compare_at_price_max":27900,"compare_at_price_varies":false,"variants":[{"id":27857385029715,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Supra LoRad MD06-EU\/SP","public_title":null,"options":["Default Title"],"price":26900,"weight":0,"compare_at_price":27900,"inventory_quantity":2,"inventory_management":"shopify","inventory_policy":"deny","barcode":"4747458065415","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/shop.hifiteam.at\/cdn\/shop\/files\/supra-lorad-md06-eu-sp-netzleiste-hifiteam-gratisversand-in-a-und-d-269.webp?v=1757539848"],"featured_image":"\/\/shop.hifiteam.at\/cdn\/shop\/files\/supra-lorad-md06-eu-sp-netzleiste-hifiteam-gratisversand-in-a-und-d-269.webp?v=1757539848","options":["Title"],"media":[{"alt":"Silberner Mains-Block mit sieben Steckdosen und Überspannungsschutz für das Supra LoRad MD06-EU\/SP","id":54668692455751,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/shop.hifiteam.at\/cdn\/shop\/files\/supra-lorad-md06-eu-sp-netzleiste-hifiteam-gratisversand-in-a-und-d-269.webp?v=1757539848"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/shop.hifiteam.at\/cdn\/shop\/files\/supra-lorad-md06-eu-sp-netzleiste-hifiteam-gratisversand-in-a-und-d-269.webp?v=1757539848","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv id=\"description\" class=\"tab-pane active\"\u003e\u003cspan class=\"wysiwyg-font-size-larger\"\u003e\u003cb\u003eLoRad Shielded Mains Blocks in Aluminium \u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab-pane active\"\u003e\n\u003cbr\u003eThe mains blocks are fully shielded from radiated electric fields by means of their aluminium chassis.\u003c\/div\u003e\n\u003cdiv class=\"tab-pane active\"\u003eThe conductive chassis drains the interference down to ground. It has to be connected to an earthed socket with an earthed mains cable, in order to work properly. For a useful degree of shielding and immunity, the mains block should be combined and employed with SUPRA LoRad shielded mains cables. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eSUPRA NIF Transient Filter \u003c\/b\u003e\u003cbr\u003eAll models are equipped with SUPRA NIF (Non-Intrusive Filtering), a mild transient filter which will not influence the transient properties of the equipment. SUPRA NIF is developed by Ben Duncan Research in England.\u003cbr\u003e\u003cbr\u003e\u003cb\u003e3-Way Surge Protection\u003c\/b\u003e\u003cbr\u003eThe SP-models, i.e MD06-BS\/SP, MD06-EU\/SP and MD06-US\/SP, are all equipped with SUPRA’s surge protection device which protects all three ways: Live to Earth, Neutral to Earth and Live to Neutral. Many other surge protectors are only Live to Neutral, and do not protect against field surges by proximate lightning. Lightning is always referred to earth.\u003cbr\u003e\u003cspan\u003eFor a correct and safe 3-way surge protection, the mains block has to be connected to an earthed wall socket.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane active\"\u003e\n\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cb\u003eMD06-EU\/SP\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e6 EU sockets, Schuko. \u003c\/div\u003e\n\u003cdiv\u003eInput connector: IEC-320 \u003c\/div\u003e\n\u003cdiv\u003e10 Amp Fuse \u003c\/div\u003e\n\u003cdiv\u003eNIF transient filter\u003c\/div\u003e\n\u003cdiv\u003e3-way Surge Protection.\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003eFor a correct and safe 3-way surge protection, the mains block has to be connected to an earthed wall socket.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv data-techdaten=\"hifiteam\"\u003e\n\u003ch3\u003eTechnische Daten\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBauart\u003c\/td\u003e\n\u003ctd\u003egeschirmte Netzleiste mit Filter und Überspannungsschutz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteckdosen\u003c\/td\u003e\n\u003ctd\u003e6 × Schuko (Supra MCH-16\/EU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEingang\u003c\/td\u003e\n\u003ctd\u003eSupra MCH-10 (IEC C14) mit Sicherung 10 A träge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBelastbarkeit\u003c\/td\u003e\n\u003ctd\u003e10 A \/ 250 V \/ 2.400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInnenverdrahtung\u003c\/td\u003e\n\u003ctd\u003e2,5 mm² OFC-Kupfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter\u003c\/td\u003e\n\u003ctd\u003eNIF-Filter (Non-Intrusive Filtering, Ben Duncan Research), Dämpfung bis 40 dB; Dose 1 ungefiltert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eÜberspannungsschutz\u003c\/td\u003e\n\u003ctd\u003e3-Wege (L–E, N–E, L–N), Typ 3; Up = 2,0 kV (L–N), 2,05 kV (L\/N–E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGehäuse\u003c\/td\u003e\n\u003ctd\u003eAluminium, geschirmt; Wandhalterung und Gummifüße im Lieferumfang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuerschnitt Gehäuse\u003c\/td\u003e\n\u003ctd\u003e90 × 50 mm (B × H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGewicht\u003c\/td\u003e\n\u003ctd\u003e1,40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eÄnderungen vorbehalten.\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n"}

Zuletzt angesehen